If you use a laser range finder instead of a soft ruler or tape measure the inte
2017-04-10

  Handheld laser range finder can use the instrument itself to measure the laser spot 200m outside the target, and can quickly calculate the area (square feet / square meter) and volume, measurement accuracy of up to ± 1 mm.

   We have a user how to use the laser range finder was investigated, received a lot of feedback, which is listed below for the best use.

1. Measure the roof spacing to determine the type of jacking required for lifting the roofing equipment.

2. Measure the height of the ceiling to determine the height of all hoisting equipment.

3. Quickly calculate the length of the cable required for the crane.

4. Set the crane collision detection interval, do not have two people standing on two lifts with a measure of the tape.

5. Measure the span of the crane track.

6. Measure the installation of emergency lights, sprayers, fire extinguishers (including ceiling height).

7. Determine the size of the room correctly to determine the chemical concentration of the clean gas fire extinguishing system.

8. Measure the distance between the fire fighting equipment (fire extinguisher, fire blanket, etc.) and the machine.

9. Measure the water level in the fire tank.

10. Used to help install the floor cabinet of a large communication room.

11. Measure the size of the room to calculate the amount of paint used.

12. Measure the size of the room to calculate the amount of ground show material.

13. Measure the height to select the appropriate ladder.

14. Record the infrared or imager or infrared thermometer found in the water or leakage location.

15. Measure the cabling length of the cable or wire.

16. Measure the linear length (ft / m) of the catheter to be installed.

17. Measure the height of the high-pressure line to check whether the ground height meets the requirements.

18. Calculate the total length of the harness.

19. Measure the pressure drop (voltage part) to calculate the required interval.

20. Measure the depth and spacing of the underground laying of the catheter.

21. Determine the length of the remaining wires in the hand.

22. Measure the distance between laying cables and various landmarks or obstructions / dangerous objects.

23. Use the range finder to track the cable when laying the cable using the transmitter / sensor tool.

24. Using the A-frame method to locate the fault point of the laying of the cable underground, you do not have to use the tape or tape measure to correctly determine the interval between the fault point and the starting point.

25. measurement and the ceiling is difficult to close the distance between objects, so as to determine the height of the cable to.

26. Measure the height and area of the ceiling to determine the length of the ceiling mounting rod and lamp holder.

27. Check the spacing within the floor sandwich.

28. Measure the spacing between power and equipment (transformers, etc.) to determine electrical safety / arc protection intervals and conduct power research.

29. Measure the installation interval of the disconnector.

30. Measure the spacing between the electrodes.

31. Measure the installation interval between the wall sockets.

32. Determine the placement point of the power outlet.

33. Measure whether the area of the distribution room is in compliance.

34. Determine the length of the conveyor (when installed)

35. Calculate the conveyor capacity according to the length.

36. Measure the equipment spacing to estimate the heat load size.

37. Determine the ventilation requirements of the equipment (air flow).

38. Check the correctness of the level and level of the tank.

Measure the power level of the power plant.

40. Check the calibration of the product round-trip interval sensor.

41. Alignment of large welding fixtures.

42. Determine the volume of industrial boilers used in powder spraying and so on.

43. Measure the height of the roof to determine the length of the flue.

44. Calculate the length of the pipe to determine the static pressure drop of the pipe.

45. to determine the drainage pipe pressure rise and fall situation.

Measure the length of the pipe.

47. Determine the size of the room to calculate the cooling, ventilation is to meet the needs, determine the equipment size.

48. Determine the type of pipe (size).

49. Determine the pipe size.

50. Measure the spacing between air handling devices.

51. Determine the spacing between the pumps and the pumping interval of the pumps to determine the specifications for the pumps and / or motors.

52. Determine the spacing of the pipeline, especially when measuring the length of the pipe behind the wall.

53. Agricultural watering measurement of the interval between the water tower, so as to calculate the size of water pressure.

54. Measure the size of the site to determine the number of spray heads required.

55. Install / repair the process to measure the length of the condensate line.

56. Determine the horizontal length of the gutter.

57. Measure the spacing between roads and boundary lines in accordance with local building regulations.

58. Determine the amount of building materials (such as keel, plywood).

59. Determine the insulation requirements (measurement volume).

60. Septic tank offset is determined.

61. Determine the depth of the groove.

62. Determine the number of gypsum boards required for surface cover.

63. Find the center of the ceiling and other major fans / lamps according to the location.

64. Determine the amount of light required for lighting fixtures according to the height of the ceiling.

65. Determine the number of power supplies required for emergency LED lighting.

66. Determine the spacing between the power supply and the LED, low-voltage lighting, and other electronic loads.

67. When the height of the ceiling is high, the interval between the lamps and the lamps to be repaired is determined.

68. Determine the spacing between network equipment in the communication room.

69. IT installation technical staff to measure the spacing between wireless network components.

70. Estimated cable length of the transmission tower.

71. Transmission tower grounding device settings; to ground pressure drop measurement and soil resistivity measurement and measurement of the distance between the ground.

72. Determine the safety separation between the microwave transmitters on the transmission tower.

73. When measuring the location of the transmission tower, measure the height of the equipment on the poles.

74. Power inspection is to measure the height of the cable on the transmission tower.


400-650-1983